Final | 10/23/2008 | 10/23/2008 | 10/23/2008 | P | PASS |
Jack Frank
|
|
|
ken Phone #: ###-#### ok
|
Conference | 10/20/2008 | 10/20/2008 | 10/20/2008 | P | DONE |
Jack Frank
|
|
|
me towner needs gfci recepts in basement, and garage, loose recepts in rms, gfci for laundry rm recepts, needs recept within 3ft of MB sinds, protect romex in island cabinet, shall not use cord plug connected power strip for island recepts, all recepts that serve kit countertops shall be on SABC, clearence bed rm closet over garage, install outdoor listed fan front porch
|
Final | 10/20/2008 | 10/20/2008 | 10/20/2008 | P | FAIL |
Jack Frank
|
|
|
ken-later afternoon please Phone #: ###-#### see added conference
|
Electrical Rough-In | 10/10/2008 | 10/10/2008 | 10/10/2008 | P | PASS |
Pat Lass
|
|
|
ken-please call at least a half hour prior to inspection Phone #: ###-#### basement AND kitchen island r/i ok
|
Electrical Rough-In | 9/24/2008 | 9/24/2008 | 9/24/2008 | P | PART |
Jack Frank
|
|
|
kenneth - after 2 please Phone #: ###-#### see added p/s
|
Permanent Service | 9/24/2008 | 9/24/2008 | 9/24/2008 | P | PASS |
Jack Frank
|
|
|
kenneth - after 2 please Phone #: ###-#### p/s u/g new ok
|
Electrical Rough-In | 9/23/2008 | 9/23/2008 | 9/23/2008 | P | PART |
Bob Reichert
|
|
|
Ken Phone #: ###-#### peninsula backsplash only ok to cover, kitchen
|
(F) Reprint permit | | | 7/18/2008 | | DONE |
|
|
|
|
Electrical Rough-In | 5/1/2008 | 5/1/2008 | 5/1/2008 | P | PART |
Pat Lass
|
|
|
ken Phone #: ###-#### upper levels ok
|
Electrical Rough-In | 4/22/2008 | 4/22/2008 | 4/22/2008 | P | FAIL |
Pat Lass
|
|
|
kenneth Phone #: ###-#### box fill and protection
|
Electrical Rough-In | 4/14/2008 | 4/14/2008 | 4/14/2008 | P | NR |
William E Thomas
|
|
|
ken Phone #: ###-#### . .1. not ready at all. . .
|
Electrical Rough-In | 3/24/2008 | 3/25/2008 | 3/25/2008 | A | NR |
Pat Lass
|
|
|
ken Phone #: ###-#### wrong type of inspection see conf.
|
Conference | 3/25/2008 | 3/25/2008 | 3/25/2008 | P | PART |
Pat Lass
|
|
|
ken Phone #: ###-#### had conf about requirements for R/I inspection
|
Electrical Rough-In | 1/8/2008 | 1/9/2008 | 1/9/2008 | A | PART |
Jack Frank
|
|
|
ken Phone #: ###-#### porch soffit ok
|
Conference | 1/3/2008 | 1/4/2008 | 1/4/2008 | A | PART |
Pat Lass
|
|
|
Ken ###-#### ///please call when on way TALKED ABOUT GENERAL REQUIREMENTS
|
Application received | | | 1/3/2008 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 1/3/2008 | | DONE |
|
|
|
|