Permit Information
Permit NumberELE08-00641
StatusFinaled
Name GRUMPYS ELECTRIC
Site Address 6606 W USTICK RD
Project Name 
Customer Numberustick
ePlanReview 
Description
Electrical Permit - New: connect house that has been moved to new location
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/26/20084/28/20084/28/2008APASS
DetailsPat Lass
Phone #: ###-#### Internet Inspection Request from: Mick Williams
Final4/23/20084/24/20084/24/2008AFAIL
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Mick Williams called, left correction notice, BCC shall install outside fixtures, shall meet 2005 NEC requirements, NEC 210.52 shall meet outlet spacing in kitchen, 210.8(A)(6) kitchen receptacles shall be gfci protected, 334.15(B) nm cable shall be protected for microwave, 110.3(B) equipment shall be installed per listing- reverse polarity by patio door, 406.5 shall install receptacle faceplate for disposal,408.4 circuit directory shall be clear, concise and explanatory for each circuit, 422.31(B) shall install disconnect for hot water heater, Note a/c shall be installed or circuiting abandoned
Permanent Service3/19/20083/20/20083/20/2008PPASS
DetailsBob Reichert
Grounding electrode is in front of house just left of front door. Phone #: ###-#### Internet Inspection Request from: Mick Williams corrections made, left correction notice to owner stating he has 24 hours to acquire permit to bring house up to code or further action will be taken such as removal of power. (Posted on garage door inside garage) p/s o/h n ok
Permanent Service3/19/20083/20/20083/19/2008PCANC
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Mick Williams Inspection cancelled from web by: Mick Williams
Permanent Service3/18/20083/19/20083/19/2008AFAIL
DetailsJack Frank
Ready for service inspection so we can get IPCo connected. Then we will turn on power and determine what needs to be fixed. Phone #: ###-#### Internet Inspection Request from: Mick Williams corr called 312.5(C) exception ser not allowed in conduit, unless it exits the top, needs concrete encased electrode, 250.104(A)(1) bond water to service not sub panel, 110.3(A&B) use proper sized lugs or terminals for conductors250.142(B) 4 wire recepts and pigtails for range and dryer, 100.12(A) seal unused 2" top of sub panel
Application received  3/18/2008 DONE
This permit was created on the web by Mick Williams