Final | 9/16/2008 | 9/17/2008 | 9/17/2008 | A | PASS |
Bob Reichert
|
|
|
Neil Phone #: ###-#### corrections made, ok to final, could not add esc comments
|
Final | 9/9/2008 | 9/9/2008 | 9/9/2008 | P | FAIL |
Bob Reichert
|
|
|
Neil Phone #: ###-#### called, left correction notice, NEC 210.11(C)(3) bathroom 20amp branch circuit shall not supply other outlets (a/c), 352.30(A) pvc shall be securely fastened within 3' of termination, 250.32(A) structure supplied by feeder shall have grounding electrode system installed,314.21 shall repair drywall for closet lights, BCC shall install fluorescent tubes, shall install under-counter lights
|
Electrical Rough-In | 8/7/2008 | 8/7/2008 | 8/7/2008 | P | PASS |
Bob Reichert
|
|
|
neil - floor heat inspection Phone #: ###-#### ok to cover floor heat, 2 baths
|
Electrical Rough-In | 6/23/2008 | 6/24/2008 | 6/24/2008 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 6/23/2008 at 10:42:45 PM. Contact: ###-####. corrections made, ric ok
|
Permanent Service | 6/24/2008 | 6/24/2008 | 6/24/2008 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 6/23/2008 at 10:42:45 PM. Contact: ###-####. corrections made, p/s u/g n ok
|
Rough-In Permanent Service | 6/23/2008 | 6/23/2008 | 6/23/2008 | P | FAIL |
Bob Reichert
|
|
|
Neil ###-#### called, left message, left correction notice, BCC all ri shall be done, all make-up shall be done, NEC 210.52(H) hallway over 10' shall have receptacle outlet installed, 210.(A)(1),(2) wall over 2' shall have receptacle installed, 314.25boxes shall have cover installed- up lighting, 300.4(A)(1) nailplate shall be installed if edge of bored hole less than 1/14" from edge of framing member, 334.30 shall secure nm cable within 12" of panel
|
Electrical Rough-In | 4/30/2008 | 4/30/2008 | 4/30/2008 | P | PASS |
Bob Reichert
|
|
|
neal Note: underground Phone #: ###-#### corrections made, ok to cover u/g house to garage
|
Electrical Rough-In | 4/28/2008 | 4/28/2008 | 4/28/2008 | P | FAIL |
Bob Reichert
|
|
|
neal Note: underground Phone #: ###-#### called, left message, left correction notice, NEC 300.5(D)(4) raceway subject to physical damage shall be schedule 80
|
Application received | | | 4/28/2008 | | |
|
|
|
|
Issue permit | | | 4/28/2008 | | |
|
|
|
|