Final | 4/9/2009 | 4/10/2009 | 4/10/2009 | A | PASS |
Pat Lass
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten
|
Final | 4/8/2009 | 4/9/2009 | 4/9/2009 | A | FAIL |
Jack Frank
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten called needs to grd metal extension ring on plastic box, box fill island recept, protect romex in island cabinet
|
Reinspection Fee (no hold) | 4/9/2009 | 4/9/2009 | 4/9/2009 | A | PASS |
Jack Frank
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten corrections fee due
|
Final | 4/6/2009 | 4/7/2009 | 4/7/2009 | A | FAIL |
Pat Lass
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten install fixtures upstairs and inuse cover on front recep. extension required for recep in cabinet recep to serve island
|
Final | 4/6/2009 | 4/6/2009 | 4/6/2009 | P | CANC |
Pat Lass
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten Inspection cancelled from web by: gary batten
|
Electrical Rough-In | 12/23/2008 | 12/24/2008 | 12/24/2008 | A | PASS |
Bob Reichert
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten corrections made, ric ok
|
Electrical Rough-In | 12/18/2008 | 12/19/2008 | 12/19/2008 | P | FAIL |
Pat Lass
|
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten protect romex within 1 1/4" of framing members and also in attic crawl spaces install all necessary boxes. hand rail is wall space for 210.52. provide 6 in free conductor at all junction/splice points. mounting screws not permited inside of nm boxes. insure boxes are flush.
|
Electrical Rough-In | 8/15/2008 | 8/15/2008 | 8/15/2008 | P | PASS |
William E Thomas
|
|
|
Redy for inspection, added 1" PVC Phone #: ###-#### Internet Inspection Request from: gary batten . .1. under slab ok for cover. . .
|
Electrical Rough-In | 8/5/2008 | 8/5/2008 | 8/5/2008 | P | PART |
Jack Frank
|
|
|
request trench inspection as early as possible, thank you Phone #: ###-#### Internet Inspection Request from: gary batten ok
|
Application received | | | 8/5/2008 | | DONE |
|
|
|
This permit was created on the web by gary batten
|