First Notice | 10/6/2008 | 10/6/2008 | 12/29/2008 | | DONE |
Bob Reichert
|
|
|
|
Telephone call | | | 12/29/2008 | | DONE |
|
|
|
tlk to a gentlement ###-#### at pro-tec regarding the final value 9:10 am
|
Final | 10/6/2008 | 10/6/2008 | 10/6/2008 | P | PASS |
Bob Reichert
|
|
|
Good afternoon Bob, The equipment is now labled and listed and ready for a final. Please call with 30min. notice so I can make sure the building is open and unlocked. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig corrections made, field evaluated by etl, ok to final, signed occupancy card
|
Final | 9/4/2008 | 9/4/2008 | 9/4/2008 | P | FAIL |
Bob Reichert
|
|
|
Hi Bob, This is the coffee roasting job site. Please indicate on the red tag that the coffee roasting equipment needs to be UL listed as a complete unit. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig left correction notice BCC 4-05-33(A)&(B) and NEC 110.3(B) equipment shall be listed by a nationally recognized testing laboratory and installed per instructions-this equipment shall be listed as an assembly by field evaluation
|
Final | 8/28/2008 | 8/29/2008 | 8/29/2008 | A | NR |
Pat Lass
|
|
|
Good morning Bob, We are ready for a re-inspection for the items you listed on the red tag. One of those items was UL listing, the owner has provided us with paper work for the CSA sticker on the equipment, I was told that this paper work will show that the CSA sticker is for approval in the US, Mucho will meet you on site to show you the paper work from the factory. Please call Mucho @ ###-#### 30min. before you get there so he can meet with you. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig equipment has to be field evaluated
|
Final | 8/19/2008 | 8/20/2008 | 8/20/2008 | A | FAIL |
Bob Reichert
|
|
|
WAYNE nOTE: PLEASE CALL 1/2 HR PRIOR TO INSPECTION Phone #: ###-#### met electrician, left correction notice, NEC 400.8 flexible cord shall not be used as a substitute for fixed wiring or where subject to physical damage,110.3 and BCC 4-05-33(A)&(B) all equipment shall be listed by a nationally recognized testing laboratory, NOTE: cottections shall be made within 10 days or further action will be taken such as removal of power
|
Application received | | | 8/19/2008 | | DONE |
|
|
|
This permit was created on the web by Wayne Craig
|