Final | 12/6/2011 | 12/7/2011 | 12/7/2011 | A | PASS |
Daryl DeGrange
|
|
|
joe Phone #: ###-#### final ok
|
ELE-Aging Inspection | 11/24/2011 | 11/24/2011 | 12/2/2011 | | DONE |
Daryl DeGrange
|
|
|
still under construction
|
Final | 12/1/2011 | 12/2/2011 | 12/2/2011 | A | FAIL |
Daryl DeGrange
|
|
|
early as possible, at least before 10:30 --Joe ###-#### Corrections not done Conduits at service need straped,empty breaker spaces require blank covers, breaker tie, label panel, install ko plugs in j-box, identify current carring conductor
|
Telephone call | | | 11/23/2011 | | DONE |
Tisha Gallop
|
|
|
received phone call from Joseph want to reopen permits; per Bob A. charge 2 hr admin fee on building permit then can reopen bld, ele, mech permit to get final inspections.
|
Change Status to I | | | 11/23/2011 | | DONE |
Tisha Gallop
|
|
|
per bob A ok to reopen permit, if homeowner pays 2 hr admin fee on building permit
|
(F) Reprint permit | | | 11/23/2011 | | DONE |
|
|
|
|
ELE-Aging Inspection | 7/7/2010 | 7/7/2010 | 7/7/2010 | | DONE |
Bob Reichert
|
|
|
see doc expire
|
DOC - Permit Expired | 7/7/2010 | 7/7/2010 | 7/7/2010 | A | PASS |
Bob Reichert
|
|
|
no activity
|
Permanent Service | 1/20/2009 | 1/20/2009 | 1/20/2009 | P | PASS |
Pat Lass
|
|
|
joe Phone #: ###-#### P/S O/H N Ok
|
Permanent Service | 1/14/2009 | 1/15/2009 | 1/15/2009 | A | CANC |
Bob Reichert
|
|
|
joe Phone #: ###-#### wrong type request, see conference, no esc this project
|
Conference | 1/15/2009 | 1/15/2009 | 1/15/2009 | A | DONE |
Bob Reichert
|
|
|
joe Phone #: ###-#### talked to owner, told to pull conductor into meter lug so that insulation not damaged, drive in ground rods, use plastic bushing for ground wire abrasion protection, add bond bushing for nipple into panel, add conduit strap for riser, no esc this project
|
Rough-In Permanent Service | 10/9/2008 | 10/9/2008 | 10/9/2008 | A | PASS |
Pat Lass
|
|
|
Joe- call 30 mins prior for access Phone #: ###-#### no esc in project
|
Rough-In Permanent Service | 9/4/2008 | 9/5/2008 | 9/5/2008 | A | PART |
Pat Lass
|
|
|
please call 30 min prior to meet you there//Joseph ###-#### upstairs ceiling ok
|
Issue PAID IN FULL permit | | | 9/4/2008 | | DONE |
|
|
|
|
Application received | | | 9/4/2008 | | |
|
|
|
|