First Notice | 11/18/2008 | 11/18/2008 | 2/25/2009 | | DONE |
Pat Lass
|
|
|
|
Final | 11/18/2008 | 11/18/2008 | 11/18/2008 | P | PASS |
Pat Lass
|
|
|
this will be for a final inspection please. Contact is Justin Metcalf. Thank you and have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw no esc in project
|
Electrical Rough-In | 10/30/2008 | 10/31/2008 | 10/31/2008 | A | PART |
Pat Lass
|
|
|
This inspection will be for a partial cieling inspection. Contact is Mark Hood. Thank you and have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw main ceiling area ok
|
Electrical Rough-In | 10/28/2008 | 10/28/2008 | 10/28/2008 | P | FAIL |
Bob Reichert
|
|
|
This inspection will be for a partial cieling. Contact is Mark Hood. Thank you and have a grea day Phone #: ###-#### Internet Inspection Request from: Laura Longshawn met electrician, left correction notice, BCC no violations shall be retained, NEC 300.11(B) wiring in ceiling shall not be supported by ceiling or its support wires (low voltage), 110.26 sufficient work space shall be provide about electricqal equipment (panel in ceiling), 725.25 abandoned cable shall be removed, no esc this project
|
Electrical Rough-In | 10/14/2008 | 10/15/2008 | 10/15/2008 | A | PASS |
Bob Reichert
|
|
|
This inspection will be for a partial wall rough in. Contact name is Mark Hood. Thank you and have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw walls only anop, phase 2 ok to cover no esc this project
|
Electrical Rough-In | 9/26/2008 | 9/26/2008 | 9/26/2008 | P | PART |
Pat Lass
|
|
|
this will be for a partial cieling inspection please. Contact will be Mark Hood. Thank you and have a great day Phone #: ###-#### Internet Inspection Request from: Laura Longshawpartial ceiling phase 1 ok
|
Electrical Rough-In | 9/25/2008 | 9/25/2008 | 9/25/2008 | P | PART |
Pat Lass
|
|
|
This inspection will be a rough in on the teller line walls. Contact will be Mark Hood. Thank you and have a great day Phone #: ###-#### Internet Inspection Request from: Laura Longshaw teller line ok
|
Electrical Rough-In | 9/25/2008 | 9/25/2008 | 9/25/2008 | P | CANC |
Pat Lass
|
|
|
This inspection will be for a rough in and the teller line walls. Contact will be Mark Hood. Thank you and have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw Inspection cancelled from web by: Laura Longshaw
|
Rough-In Permanent Service | 9/18/2008 | 9/19/2008 | 9/19/2008 | A | PART |
Pat Lass
|
|
|
This will be for another partial wall inspection. Contact is Mark Hood. Thank you and have a great day Phone #: ###-#### Internet Inspection Request from: Laura Longshaw Partial wall and hardlid ok phase 1
|
Electrical Rough-In | 9/15/2008 | 9/15/2008 | 9/15/2008 | P | PART |
Pat Lass
|
|
|
Partial rough-in inspection on walls.Contact will be Mark Hood ###-#### Thanks Phone #: ###-#### Internet Inspection Request from: Laura Longshaw outside walls phase 1 ok
|
Owner Supplied Equipment | | | 9/15/2008 | | |
|
|
|
|
Application received | | | 9/15/2008 | | DONE |
|
|
|
This permit was created on the web by Laura Longshaw
|