Final | 11/25/2008 | 11/25/2008 | 11/25/2008 | P | PASS |
Pat Lass
|
|
|
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack
|
Electrical Rough-In | 10/29/2008 | 10/30/2008 | 10/30/2008 | A | PART |
Jack Frank
|
|
|
pool lights potting compound Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack ok both fixtures
|
Electrical Rough-In | 10/6/2008 | 10/7/2008 | 10/7/2008 | A | PART |
Pat Lass
|
|
|
ug conduit; turned up conduit for j-box Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack Underground for wet nitch fixtures is ok. If other wiring is in the conduits it must be 5ft. from the pool. called Lee and he said he wold find out.
|
Electrical Rough-In | 10/4/2008 | 10/6/2008 | 10/6/2008 | A | FAIL |
Jack Frank
|
|
|
ug conduit Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called over 360 degrees of bends in u/g pvc from house to pool
|
Electrical Rough-In | 9/25/2008 | 9/26/2008 | 9/26/2008 | P | PART |
Pat Lass
|
|
|
pool bonding Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack pool bond ok
|
Application received | | | 9/25/2008 | | DONE |
|
|
|
This permit was created on the web by Lee VanSchoiack
|