Final | 5/26/2009 | 5/26/2009 | 5/26/2009 | P | PASS |
Jack Frank
|
|
|
Sean Phone #: ###-####
|
Final | 5/24/2009 | 5/26/2009 | 5/26/2009 | A | FAIL |
Jack Frank
|
|
|
please renspect, thank you Phone #: ###-#### Internet Inspection Request from: Sean Peltier no power to 1/2 of basement, called
|
Final | 5/21/2009 | 5/22/2009 | 5/22/2009 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Sean Peltier job not reasdy only had access to upstairs, clearence for closet fixtures, install front entry coat closet fixture, needs gfci for garage door opener, no access to down stairs
|
Reinspection Fee (no hold) | 5/22/2009 | 5/22/2009 | 5/22/2009 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Sean Peltier fee due job N R
|
Conference | 5/21/2009 | 5/21/2009 | 5/21/2009 | A | DONE |
Bob Reichert
|
|
|
need info on an odd island Phone #: ###-#### Internet Inspection Request from: Sean Peltier talked about receptacles at edge of cook-top in backsplash being ok for island receptacles
|
Permanent Service | 5/5/2009 | 5/6/2009 | 5/6/2009 | P | PASS |
Mike Kinnear
|
|
|
Phone #: ###-#### Internet Inspection Request from: Sean Peltier p/s u/g n ok
|
Rough-In Permanent Service | 2/4/2009 | 2/4/2009 | 2/4/2009 | P | PASS |
Pat Lass
|
|
|
Please reinspect Phone #: ###-#### Internet Inspection Request from: Sean Peltier
|
Rough-In Permanent Service | 2/3/2009 | 2/4/2009 | 2/4/2009 | A | FAIL |
Jack Frank
|
|
|
please reinspect, corrections made after talking with Bob. Phone #: ###-#### Internet Inspection Request from: Sean Peltier corr not made still needs nail plates called
|
Reinspection Fee (no hold) | 2/4/2009 | 2/4/2009 | 2/4/2009 | A | PASS |
Jack Frank
|
|
|
please reinspect, corrections made after talking with Bob. Phone #: ###-#### Internet Inspection Request from: Sean Peltier corr fee due
|
Rough-In Permanent Service | 1/30/2009 | 2/2/2009 | 2/2/2009 | A | FAIL |
Bob Reichert
|
|
|
shawn Phone #: ###-#### called contractor, left correction notice, NEC 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member or be protected by steel plate, 210.70(A)(2) shall provide lighting outlet for garage door entrance, 110.14(A) gec terminal shall provide thoroughly good connection, BCC shall provide box for microwave and cable in basement and make-up for both
|
Rough-In Permanent Service | 1/20/2009 | 1/20/2009 | 1/20/2009 | P | FAIL |
Mike Kinnear
|
|
|
Phone #: ###-#### Internet Inspection Request from: Sean Peltier fail service no grounding electrode -- ri no approved set of prints on job site framing may not be completed called contractor & advised
|
Application received | | | 1/20/2009 | | DONE |
|
|
|
This permit was created on the web by Sean Peltier
|