ELE-Aging Inspection | 8/16/2010 | 8/16/2010 | 8/16/2010 | | CANC |
Jack Frank
|
|
|
|
DOC - Permit Expired | 8/16/2010 | 8/16/2010 | 8/16/2010 | A | PASS |
Jack Frank
|
|
|
no activity
|
ELE-Aging Inspection | 6/16/2010 | 6/16/2010 | 6/17/2010 | | CANC |
Jack Frank
|
|
|
no activity
|
ELE-Aging Inspection | 4/16/2010 | 4/16/2010 | 4/20/2010 | | CANC |
Jack Frank
|
|
|
|
Electrical Rough-In | 1/27/2009 | 1/27/2009 | 1/27/2009 | P | PASS |
Bob Reichert
|
|
|
joe Phone #: ###-#### corrections made ric ok, kitchen and dining room only, no esc this project
|
Electrical Rough-In | 1/26/2009 | 1/27/2009 | 1/27/2009 | A | FAIL |
Bob Reichert
|
|
|
after 9 please-joseph Phone #: ###-#### met owner, corrections 300.4 (A)&(D) 1/14" for edge of holes and nm cable shall be maintained, 210.52 (B)(2) circuits for outdoor recpt and light shall not be on dining room circuit, no esc this project
|
Electrical Rough-In | 1/23/2009 | 1/26/2009 | 1/26/2009 | A | FAIL |
Jack Frank
|
|
|
joe Phone #: ###-#### met with owner, I explained NEC requirements for wall and countertop outlet spacing, box fill , 6" free length, what can be on small appliance branch circuits , owner said it was his house , and he thought he did not have to wire it to code
|
Electrical Rough-In | 1/21/2009 | 1/22/2009 | 1/22/2009 | A | CANC |
Mike Kinnear
|
|
|
jim Note: please call 1/2 hr prior to inspection Phone #: ###-#### wrong type inspection no esc permit in project.
|
Conference | 1/22/2009 | 1/22/2009 | 1/22/2009 | A | DONE |
Mike Kinnear
|
|
|
jim Note: please call 1/2 hr prior to inspection Phone #: ###-#### conf with father inlaw advised as much as i could. the owner needs to get appointment with bob for another conf.
|
Application received | | | 1/20/2009 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 1/20/2009 | | DONE |
Alexandra L. DeYoung
|
|
|
|