Final | 9/14/2010 | 9/15/2010 | 9/16/2010 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok final
|
Electrical Rough-In | 6/10/2010 | 6/11/2010 | 6/11/2010 | A | PASS |
Bob Reichert
|
|
|
Floor heat install in master bath and 2nd floor bath Inspection requested from web by: Therrin Robertson Phone #: ###-#### ric ok
|
Rough-In Permanent Service | 4/27/2010 | 4/27/2010 | 4/27/2010 | A | PASS |
Doug A Poedy
|
|
|
Inspection requested from web by: Therrin Robertson Phone #: ###-####
|
Rough-In Permanent Service | 4/26/2010 | 4/26/2010 | 4/26/2010 | A | CANC |
Bob Reichert
|
|
|
Uefer in crawl space Inspection requested from web by: Therrin Robertson Phone #: ###-#### see ri and p/s
|
Electrical Rough-In | 4/26/2010 | 4/26/2010 | 4/26/2010 | A | FAIL |
Bob Reichert
|
|
|
Uefer in crawl space Inspection requested from web by: Therrin Robertson Phone #: ###-#### called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(D) shall provide recptacle within 3' of bath sink, 210.52(H) shall provide receptacle in 10' hall, 362.30(A) shall strap ent within 3' of box, 334.30 shall not staple nm on edge, 334.23 shall protect cable within 6' of attc access, BCC shall provide box to terminate nm cable, NOTE corrections shall be made within 5 working days
|
Permanent Service | 4/26/2010 | 4/26/2010 | 4/26/2010 | A | PASS |
Bob Reichert
|
|
|
Uefer in crawl space Inspection requested from web by: Therrin Robertson Phone #: ###-#### p/s u/g n ok
|
Rough-In Permanent Service | 4/22/2010 | 4/23/2010 | 4/23/2010 | A | CANC |
Doug A Poedy
|
|
|
Inspection requested from web by: Therrin Robertson Phone #: ###-####. Please make as early as possible. Thanks.. Contractor cancelled.
|
Rough-In Permanent Service | 4/22/2010 | 4/22/2010 | 4/22/2010 | P | CANC |
Doug A Poedy
|
|
|
Inspection requested from web by: Therrin Robertson Phone #: ###-####
|
Rough-In Permanent Service | 4/22/2010 | 4/22/2010 | 4/22/2010 | A | CANC |
Doug A Poedy
|
|
|
Inspection requested from web by: Therrin Robertson Phone #: ###-####. Please make as early as possible. Thanks.
|
Application received | | | 4/22/2010 | | DONE |
|
|
|
This permit was created on the web by Therrin Robertson
|