Final | 9/2/2010 | 9/3/2010 | 9/3/2010 | A | PASS |
Jack Frank
|
|
|
JIm Phone #: ###-####
|
Final | 9/1/2010 | 9/2/2010 | 9/2/2010 | A | NH |
Jack Frank
|
|
|
Jim Phone #: ###-#### called no access
|
Permanent Service | 8/4/2010 | 8/5/2010 | 8/5/2010 | A | PASS |
Jack Frank
|
|
|
Jim Phone #: ###-#### p/s u/g new ok
|
Permanent Service | 8/4/2010 | 8/4/2010 | 8/4/2010 | P | PASS |
Jack Frank
|
|
|
jim Phone #: ###-#### p/s u/g new ok
|
Electrical Rough-In | 5/27/2010 | 5/28/2010 | 5/28/2010 | A | PASS |
Doug A Poedy
|
|
|
jim Phone #: ###-####
|
Rough-In Permanent Service | 5/26/2010 | 5/27/2010 | 5/27/2010 | A | FAIL |
Bob Reichert
|
|
|
jim Phone #: ###-#### called, left correction notice, BC shall provide correct address- builder said this was 1683, not 1681, NEC 314.20 in combustible material, boxes shall be flush with finished surface at garage, 312.5 all conductors entering enclosures shall have abrasion protection, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.23 cables in accessible attics shall comply with 320.23, 250.28(A) shall provide main bonding jumper, 210.52(A)(1) shall provide convenience receptacle under counter-top, NOTE: corrections shall be made in 5 working days or further action will be taken
|
Application received | | | 5/26/2010 | | |
|
|
|
|
Issue permit | | | 5/26/2010 | | DONE |
|
|
|
|