Final | 7/25/2012 | 7/26/2012 | 7/26/2012 | A | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Louis Keller corrections done final ok
|
Final | 6/22/2012 | 6/25/2012 | 6/25/2012 | A | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Louis Keller NEC 408.7 NEC 250.32(B)4 Too many grounding conductors under one lug in grounding bar NEC 680.22(5)(B) GFCI protection for pool pump
|
ELE-Aging Inspection | 6/22/2012 | 6/22/2012 | 6/22/2012 | | DONE |
Daryl DeGrange
|
|
|
contacted electrical contractor, Louis Keller would call for final
|
ELE-Aging Inspection | 3/23/2012 | 3/23/2012 | 3/29/2012 | | PASS |
Daryl DeGrange
|
|
|
Notified electrical contractor if required final inspection
|
Rough-In Permanent Service | 4/26/2011 | 4/27/2011 | 4/27/2011 | A | PASS |
Daryl DeGrange
|
|
|
Bonding and underground Phone #: ###-#### >> Inspection requested via web by Louis Keller rough-in ok underground- bonding
|
Electrical Rough-In | 4/22/2011 | 4/25/2011 | 4/25/2011 | A | PASS |
Daryl DeGrange
|
|
|
We will schedule the remaining rebar and underground on tuesday Phone #: ###-#### >> Inspection requested via web by Louis rough-in ok cover trench
|
Application received | | | 4/21/2011 | | DONE |
|
|
|
This permit was created on the web by Louis Keller
|