Final | 9/9/2014 | 9/10/2014 | 9/10/2014 | A | PASS |
Daryl DeGrange
|
|
|
John Phone #: ###-#### correction done, final ok
|
Electrical Rough-In | 6/11/2014 | 6/12/2014 | 6/12/2014 | A | FAIL |
Daryl DeGrange
|
|
|
John Phone #: ###-#### Not all corrections have been completed, non GFCI receptacles, open splice still exist.
|
ELE-Aging Inspection | 6/11/2014 | 6/11/2014 | 6/11/2014 | | DONE |
Daryl DeGrange
|
|
|
Homeowner has completed his shop and is ready for a final.
|
ELE-Aging Inspection | 3/12/2014 | 3/12/2014 | 3/19/2014 | | DONE |
Daryl DeGrange
|
|
|
still under construction
|
ELE-Aging Inspection | 11/13/2013 | 11/13/2013 | 11/13/2013 | | DONE |
Daryl DeGrange
|
|
|
still under construction
|
ELE-Aging Inspection | 7/8/2013 | 7/8/2013 | 7/10/2013 | | DONE |
Daryl DeGrange
|
|
|
still waiting for homeowner to return to town
|
ELE-Aging Inspection | 4/5/2013 | 4/5/2013 | 4/8/2013 | | DONE |
Daryl DeGrange
|
|
|
Homeowner will call for final when he returns to town
|
Final | 1/4/2013 | 1/7/2013 | 1/7/2013 | A | FAIL |
Bob Reichert
|
|
|
John Phone #: ###-#### met owner, shall provide receptacles for lights in north room (no open splices), shall use so cord with plug, cover switch plate in room off main room, shall provide gfci receptacles in main room, shall wire receptacle correctly on west wall, fix and recall
|
ELE-Aging Inspection | 12/27/2012 | 12/27/2012 | 12/27/2012 | | DONE |
Daryl DeGrange
|
|
|
Homeowner said he was ready for final inspection and would call it in
|
ELE-Aging Inspection | 9/27/2012 | 9/27/2012 | 10/2/2012 | | DONE |
Daryl DeGrange
|
|
|
home owner will call for final
|
ELE-Aging Inspection | 5/17/2012 | 5/17/2012 | 5/25/2012 | | DONE |
Jack Frank
|
|
|
wsuc
|
ELE-Aging Inspection | 2/16/2012 | 2/16/2012 | 2/16/2012 | | DONE |
Jack Frank
|
|
|
wsuc
|
Electrical Rough-In | 10/14/2011 | 10/14/2011 | 10/14/2011 | A | PASS |
Jack Frank
|
|
|
r/i for shop ok
|
Electrical Rough-In | 10/7/2011 | 10/10/2011 | 10/10/2011 | A | FAIL |
Jack Frank
|
|
|
john please call 30 min before going out Phone #: ###-#### owner not doing work, correction posted, box fill boxes shall be flush with siding, needs switch and light outdoor exits, remove old wiring and breakers subjected too heat from fire, required clearence for panel , needs 2 grd rods, needs WR and TR recepts, needs backfed clip for main breaker remove or correct all wiring in violation of NEC, wiring too pump
|
Conference | 4/28/2011 | 4/28/2011 | 4/28/2011 | P | DONE |
Jack Frank
|
|
|
John Phone #: ###-#### owner has wired and covered job already job is so bad needs to start over explained NEC requirements, also all wiring subjected to the heat of the fire, and all wiring done by electrician without permit shall be replaced
|
Application received | | | 4/28/2011 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/28/2011 | | DONE |
Christina Prado
|
|
|
|