Final | 9/7/2011 | 9/8/2011 | 9/8/2011 | A | PASS |
Daryl DeGrange
|
|
|
Robert Phone #: ###-#### final ok unattach garage
|
Final | 9/6/2011 | 9/7/2011 | 9/7/2011 | A | FAIL |
Daryl DeGrange
|
|
|
BOB-Please call at least 30 mins prior to inspection Phone #: ###-#### NEC 210.8(2) Garage shall have GFCI protection
|
Electrical Rough-In | 8/24/2011 | 8/25/2011 | 8/25/2011 | A | PASS |
Daryl DeGrange
|
|
|
Robert Phone #: ###-#### rough-in ok cover
|
Electrical Rough-In | 8/24/2011 | 8/24/2011 | 8/24/2011 | P | FAIL |
Daryl DeGrange
|
|
|
Trench covered before inspection, contractor dug up two two locations. NEC 3004 NM cable shall be stapled within 12 inches of an receptacle or light box. NEC 334.4 (A) (B) Edge of bored holes and NM cable shall be 1 1/4 from edge of framimg member. NEC 334.25 Bending radius The radius of the curve of the inner edge of any bend during or after installation shall not be less than five times the diameter of the cable
|
Conference | 8/24/2011 | 8/24/2011 | 8/24/2011 | P | DONE |
Daryl DeGrange
|
|
|
Talked with general contractor-home owner not available-wiring allready installed before conference meeting. some electrical corrections needed before covering
|
Application received | | | 8/24/2011 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/24/2011 | | DONE |
|
|
|
|