Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberELE11-02635
StatusFinaled
Name CORNERSTONE ELECTRIC
Site Address 2019 N 9TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Alteration: Remodel
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/10/20121/11/20121/11/2012APASS
DetailsDaryl DeGrange
Cal, Phone #: ###-#### >> Inspection requested via web by cal crosby correction done final ok
Final1/9/20121/9/20121/9/2012PFAIL
DetailsDaryl DeGrange
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby NEC 210.8(A)(5) Unfinished basements receptacle shall have GFCI protection NEC 210.52(A)(2) Any bedroom wall space 2 ft. or more shall have an receptacle
Electrical Rough-In11/28/201111/29/201111/29/2011PPASS
DetailsDaryl DeGrange
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby rough-in ok cover
Permanent Service11/22/201111/22/201111/22/2011PPASS
DetailsDaryl DeGrange
Cal Phone #: ###-#### p/s o/h rec ok
Issue PAID IN FULL permit  11/21/2011 DONE
Payment received via Govolutions
Application received  11/21/2011 DONE
This permit was created on the web by cal crosby