Final | 7/13/2015 | 7/14/2015 | 7/14/2015 | A | PASS |
Rex Boyles
|
|
|
Master bath rough in insp. Thanks Phone #: ###-#### Inspection requested via web by John VanZandt r/i mstr. bath ok
|
ELE-Aging Inspection | 4/14/2015 | 4/14/2015 | 4/17/2015 | | DONE |
Rex Boyles
|
|
|
too busy
|
ELE-Aging Inspection | 1/13/2015 | 1/13/2015 | 1/14/2015 | | DONE |
Rex Boyles
|
|
|
too busy
|
ELE-Aging Inspection | 10/14/2014 | 10/14/2014 | 10/14/2014 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 7/15/2014 | 7/15/2014 | 7/15/2014 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 4/15/2014 | 4/15/2014 | 4/16/2014 | | DONE |
Bob Reichert
|
|
|
called, still under construction
|
ELE-Aging Inspection | 1/14/2014 | 1/14/2014 | 1/15/2014 | | CANC |
Bob Reichert
|
|
|
|
ELE-Aging Inspection | 10/15/2013 | 10/15/2013 | 10/17/2013 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 7/15/2013 | 7/15/2013 | 7/22/2013 | | CANC |
Bob Reichert
|
|
|
|
Electrical Rough-In | 4/15/2013 | 4/16/2013 | 4/16/2013 | A | PASS |
Bob Reichert
|
|
|
Rough insp. for kitchen and basement Phone #: ###-#### >> Inspection requested via web by John VanZandt called, ok cover basement and upstairs except for panel area
|
ELE-Aging Inspection | 1/30/2013 | 1/30/2013 | 1/30/2013 | | DONE |
Bob Reichert
|
|
|
still under construction
|
Electrical Rough-In | 10/29/2012 | 10/30/2012 | 10/30/2012 | A | PASS |
Bob Reichert
|
|
|
Floor heat insp. call 30 mins ahead for access Phone #: ###-#### >> Inspection requested via web by John VanZandt ok cover floor heat dining room
|
Electrical Rough-In | 3/15/2012 | 3/16/2012 | 3/16/2012 | A | PASS |
Bob Reichert
|
|
|
Floor heat inspection + 3 bathrooms Phone #: ###-#### >> Inspection requested via web by John VanZandt ok cover floor heat
|
Electrical Rough-In | 12/21/2011 | 12/22/2011 | 12/22/2011 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt corrections made, ri ok
|
Electrical Rough-In | 12/21/2011 | 12/21/2011 | 12/21/2011 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt corrections not all done
|
Electrical Rough-In | 12/19/2011 | 12/20/2011 | 12/20/2011 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt called, left correction notice, NEC 300.4(A)(D) edge of bored holes, nm, raceways shall be 1 1/4" from edge of framing members, 342.46 shall provide bushing for fmc, 314.17(C) shall staple nm within 8" of box, 334.30 shall not staple nm on edge, 334.80 shall derate nm if over 2 cables in hole, 250.86 shall ground metal boxes, BCC all make-up shall be done, boxes installed, wire boxes, prepare interface for old wall, check into 2' wall space for outlets top of stairs
|
Permanent Service | 12/15/2011 | 12/15/2011 | 12/15/2011 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt p/s o/h n ok
|
Permanent Service | 12/9/2011 | 12/9/2011 | 12/9/2011 | P | NR |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt talked about concrete encased electrode not being deep enough or ground rods, and to recall
|
Issue PAID IN FULL permit | | | 12/9/2011 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/9/2011 | | DONE |
|
|
|
This permit was created on the web by John VanZandt
|