Final | 1/24/2014 | 1/27/2014 | 1/27/2014 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Louis Keller Final ok
|
Final | 1/14/2014 | 1/17/2014 | 1/17/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Please call customer when you are on the way to the address so they can make sure to be home. Phone #: ###-#### >> Inspection requested via web by Louis Keller 680.22(A)- A 15 or 20 amp receptical outlet shall be located with in 20 foot of pool edge but not less than 6 foot from pool. 680.22(B)- Outlets supplying pool pumps motors shall have GFCI protection. 408.4- Circuit directory shall legibly identified. 210.8- All outdoor receptical outlets shall have GFCI protection. Patio 406.8(B)- Recepticals located on patio shall be weater resistant type
|
ELE-Aging Inspection | 11/1/2013 | 11/1/2013 | 11/1/2013 | | DONE |
Rock A. Hudson
|
|
|
Waiting on owner
|
ELE-Aging Inspection | 8/2/2013 | 8/2/2013 | 8/2/2013 | | DONE |
Rock A. Hudson
|
|
|
Spoke with contractor on phone.
|
Electrical Rough-In | 6/28/2012 | 6/28/2012 | 6/28/2012 | P | PASS |
Doug A Poedy
|
|
|
potting bonding and underground Phone #: ###-#### >> Inspection requested via web by Louis Keller. Pooting and conduit near hot tub ok.
|
Final | 6/28/2012 | 6/28/2012 | 6/28/2012 | P | CANC |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Louis Keller Inspection cancelled from web by: Louis Keller
|
Electrical Rough-In | 5/17/2012 | 5/18/2012 | 5/18/2012 | A | PASS |
Daryl DeGrange
|
|
|
Underground reinspect Phone #: ###-#### >> Inspection requested via web by Louis Keller corrections done rough-in ok cover underground.
|
Electrical Rough-In | 5/16/2012 | 5/17/2012 | 5/17/2012 | A | FAIL |
Daryl DeGrange
|
|
|
Underground Phone #: ###-#### >> Inspection requested via web by Louis Keller NEC 352.24 to tight of radius NEC 352.26 360 degrees total per run
|
Final | 5/16/2012 | 5/17/2012 | 5/16/2012 | A | CANC |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Louis Keller Inspection cancelled from web by: Louis Keller
|
Electrical Rough-In | 4/19/2012 | 4/20/2012 | 4/20/2012 | A | PASS |
Daryl DeGrange
|
|
|
Bonding Phone #: ###-#### >> Inspection requested via web by Louis Keller rough-in ok cover pool bonding & wet niche fixture
|
Electrical Rough-In | 4/19/2012 | 4/19/2012 | 4/19/2012 | P | PASS |
Bob Reichert
|
|
|
Underground reinspect Phone #: ###-#### >> Inspection requested via web by Louis Keller corrections made, u/g and pool bond ok
|
Electrical Rough-In | 4/18/2012 | 4/19/2012 | 4/19/2012 | A | FAIL |
Jack Frank
|
|
|
Underground reinspect Phone #: ###-#### >> Inspection requested via web by Louis Keller called violation not corrected
|
Electrical Rough-In | 4/18/2012 | 4/18/2012 | 4/18/2012 | P | FAIL |
Daryl DeGrange
|
|
|
underground Phone #: ###-#### >> Inspection requested via web by Louis Keller NEC 352.26 No more than 360 degree total between pull points
|
Issue PAID IN FULL permit | | | 4/17/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/17/2012 | | DONE |
|
|
|
This permit was created on the web by Louis Keller
|