Final | 11/29/2012 | 11/30/2012 | 11/30/2012 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov ok final, signed card
|
Final | 11/25/2012 | 11/26/2012 | 11/26/2012 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, too many violations to write correction notice, some are: wrong size bond wire for intersystem bond, kitchen recpt phase, covers missing, plugs not flush with covers, loose receptacles, light over closet shelf, check for 50% lighting energy efficient
|
Rough-In Permanent Service | 10/31/2012 | 10/31/2012 | 10/31/2012 | A | CANC |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Inspection cancelled from web by: daniel bibikov
|
Rough-In Permanent Service | 10/22/2012 | 10/23/2012 | 10/23/2012 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov ri ok, p/s u/g n ok, 5 meters req'd
|
Fees Due Hold | 10/23/2012 | | 10/23/2012 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 10/23/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Rough-In Permanent Service | 10/22/2012 | 10/22/2012 | 10/22/2012 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, corrections not done, ground clamps loose, shall add nailplates as req'd, fee due
|
Reinspection Fee (no hold) | 10/22/2012 | 10/22/2012 | 10/22/2012 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov see corrections
|
Rough-In Permanent Service | 10/18/2012 | 10/18/2012 | 10/18/2012 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, ground crimps loose, shall protect nm cable within 6' of attic access
|
Conference | 10/11/2012 | 10/12/2012 | 10/12/2012 | A | DONE |
Bob Reichert
|
|
|
Please call half hour before coming out after 9 would be great Phone #: ###-#### >> Inspection requested via web by daniel bibikov reviewed job and corrections
|
Issue PAID IN FULL permit | | | 10/11/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Rough-In Permanent Service | 10/10/2012 | 10/11/2012 | 10/11/2012 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, too many violations to list, needs complete re-inspection, check ground connections in boxes, free length conductor, outlet spacing, flush boxes, boxes to terminate nm cable, house panel to feed common receptacles for a/c units, 1 1/4", attic access, ground metal water pipe for riser room, safe off stairs for fall protection
|
Issue PAID IN FULL permit | | | 10/10/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/10/2012 | | DONE |
|
|
|
This permit was created on the web by daniel bibikov
|
First Notice | 11/30/2012 | 11/30/2012 | | | |
Bob Reichert
|
|
|
|