Final | 3/18/2013 | 3/18/2013 | 3/18/2013 | P | PASS |
Bob Reichert
|
|
|
Ryan Phone #: ###-#### corrections made, ok final
|
Final | 3/15/2013 | 3/15/2013 | 3/15/2013 | P | FAIL |
Rock A. Hudson
|
|
|
Final. CJ is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut NEC 422.30- A means shall be provided to disconnect all ungrounded conductors to each appliance. NEC 410.16 C1- Luminaires in cloths closets, surface mounted, shall have a minimum clearence of 12" for incandescent type fixures. NEC 406.5 Floor recepticals shall be covered.
|
Rough-In Permanent Service | 11/28/2012 | 11/28/2012 | 11/28/2012 | P | PASS |
Rock A. Hudson
|
|
|
Ryan is contact. Rough in and permanenet service. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Rough in ok cover p/s u/g n ok
|
Electrical Rough-In | 10/30/2012 | 10/30/2012 | 10/30/2012 | P | PASS |
Bob Reichert
|
|
|
JUST A SOFFIT INSPECTION. Ryan is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut ok cover soffits only
|
Issue PAID IN FULL permit | | | 10/30/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/30/2012 | | DONE |
|
|
|
This permit was created on the web by Chris Chesnut
|