Final | 2/19/2013 | 2/20/2013 | 2/20/2013 | A | PASS |
Daryl DeGrange
|
|
|
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey final ok
|
Final | 2/12/2013 | 2/13/2013 | 2/13/2013 | A | FAIL |
Bob Reichert
|
|
|
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, shall strap riser, provide correct panel schedule, provide gfci receptacles in garage, might add rear receptacle, will recall
|
Electrical Rough-In | 1/15/2013 | 1/16/2013 | 1/16/2013 | A | PASS |
Daryl DeGrange
|
|
|
if you can give me a call 30 min in advance i would like to try to meet you there. thanks Phone #: ###-#### >> Inspection requested via web by Neal Rumsey corrections completed rough-in ok cover
|
Electrical Rough-In | 1/15/2013 | 1/15/2013 | 1/15/2013 | P | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Not all corrections completed
|
Electrical Rough-In | 1/13/2013 | 1/14/2013 | 1/14/2013 | P | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey NEC 300.4 Nail plates needed, Restaple NM cable that is within 1 1/4 in. of framing member edge NEC 334.30 NM cable shall be stapled within 12 in. of every outlet box and service panel. NEC 210.52 Outside outlet (Front of house were wall is open)
|
Issue PAID IN FULL permit | | | 1/13/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/13/2013 | | DONE |
|
|
|
This permit was created on the web by Neal Rumsey
|
Reinspection Fee (no hold) | 1/15/2013 | 1/15/2013 | | P | |
Daryl DeGrange
|
|
|
Not all corrections complete, still in need of nail plates and stapling.
|