Final | 5/30/2013 | 5/30/2013 | 5/30/2013 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson Final ok
|
Final | 5/29/2013 | 5/29/2013 | 5/29/2013 | P | NR |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson Shower trim missing, overcurrent on A/C unit over ampacity of branch circuit
|
Final | 5/27/2013 | 5/28/2013 | 5/28/2013 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson -All 120 volt 15 & 20 amp recepticals shall have GFCI protection. -Furnace disconnect shall have proper cover fit. -Garage and outdoor recepticals not working. -Office recepticals shall have covers and spark rings. -Device covers needed in basement storage room. -Basement closet fixture shall have 12" clerance to shelf.
|
Rough-In Permanent Service | 3/14/2013 | 3/14/2013 | 3/14/2013 | P | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in p/s u/g n ok Advised electrical contractor of his live temporary power pole laying on the ground with unfused conductors exposed,
|
Issue PAID IN FULL permit | | | 2/21/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/21/2013 | | DONE |
|
|
|
This permit was created on the web by Therrin Robertson
|