Permit Information
Permit NumberELE13-00705
StatusFinaled
Name SUPERIOR ELECTRICAL CONTRACTORS
Site Address 2535 N PLEASANT HILL WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/5/20137/5/20137/5/2013PPASS
DetailsRock A. Hudson
Ryan Phone #: ###-#### Final ok
Final7/3/20137/3/20137/3/2013PFAIL
DetailsBob Reichert
if no one there, call for garage code//Ryan Phone #: ###-#### called, shall provide power and locate gfci in small garage,laundry room gfci shall operate, and receptacle within 6' of sink shall be gfci protected, pantry shall be gfci protected, living room shall have receptacle by patio door, shall put receptaccle together in mbr in vanity
Rough-In Permanent Service4/5/20134/5/20134/5/2013PPASS
DetailsRock A. Hudson
ryan Phone #: ###-#### Rough in ok cover
p/s u/g n ok
Final4/5/20134/5/20134/5/2013ACANC
DetailsRock A. Hudson
Ryan is contact. FINAL. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut needed rough in permanent service
Rough-In Permanent Service4/5/20134/5/20134/5/2013PFAIL
DetailsRock A. Hudson
Ryan is contact. FINAL. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut
300.4 Nail plates needed through out
250.96 3/0 boxes- non current carrying metal parts shall be grounded
250.96 net panel outlet box shall be grounded
BCC expansion joint shall be installed in service riser
Electrical Rough-In3/27/20133/27/20133/27/2013APASS
DetailsDaryl DeGrange
Partial rough in. JUST SOFFITS. Ryan is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut r/i ok cover exterior soffits
Issue PAID IN FULL permit  3/27/2013 DONE
Payment received via Govolutions
Application received  3/27/2013 DONE
This permit was created on the web by Chris Chesnut