Final | 6/30/2013 | 7/1/2013 | 7/1/2013 | A | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Cyndi Dale final ok
|
Final | 6/26/2013 | 6/27/2013 | 6/27/2013 | A | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Cyndi Dale NEC 210.8(8)(B) all 15 and 20 ampere receptacle in bathrooms,kitchens or within 6 ft. of sink or basin shall have GFCI protection
|
Electrical Rough-In | 6/11/2013 | 6/11/2013 | 6/11/2013 | P | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Cyndi Dale correction done rough-in ok cover walls
|
Electrical Rough-In | 6/10/2013 | 6/11/2013 | 6/11/2013 | A | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Cyndi Dale Remove abandon MC cable,support MC cable were needed, Reinstall MC cable were bent over 5 time diameter of cable.
|
Issue PAID IN FULL permit | | | 5/16/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Owner Supplied Equipment | | | 5/16/2013 | | |
|
|
|
|
Application received | | | 5/16/2013 | | DONE |
|
|
|
This permit was created on the web by Cyndi Dale
|
First Notice | 7/1/2013 | 7/1/2013 | | | |
Daryl DeGrange
|
|
|
|