Final | 6/22/2015 | 6/23/2015 | 6/23/2015 | P | PASS |
Daryl DeGrange
|
|
|
Steve-would like you to come out after 1:00 Phone #: ###-#### final ok
|
Electrical Rough-In | 10/21/2013 | 10/21/2013 | 10/21/2013 | P | PASS |
Daryl DeGrange
|
|
|
Steve Phone #: ###-#### rough-in ok cover garage addition
|
Electrical Rough-In | 10/2/2013 | 10/3/2013 | 10/3/2013 | A | FAIL |
Daryl DeGrange
|
|
|
steve please call before going out Phone #: ###-#### NEC 300.4 nail plates where bored holes are less than 1 1/4 from edge of framing member. NEC 334.30 Shall staple NM cable within 12 in. box or panel support NM cable every 4 1/2 feet
|
Conference | 6/20/2013 | 6/21/2013 | 6/21/2013 | P | DONE |
Daryl DeGrange
|
|
|
Stephan or ###-#### please call at least 30 mins prior to inspection Phone #: ###-#### Discussed with homeowner requirements for wiring garage addition
|
Application received | | | 6/20/2013 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/20/2013 | | DONE |
Barbara Stitt
|
|
|
|