Final | 8/26/2013 | 8/27/2013 | 8/27/2013 | P | PASS |
Rock A. Hudson
|
|
|
Lock box is 3975. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Final ok
|
Fees Due Hold | 8/9/2013 | | 8/12/2013 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 8/12/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Rough-In Permanent Service | 8/7/2013 | 8/8/2013 | 8/8/2013 | A | PASS |
Rock A. Hudson
|
|
|
Lock box combo is 3975. Let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Rough in ok cover p/s o/h n ok
|
Conference | 6/28/2013 | 6/28/2013 | 6/28/2013 | P | DONE |
Rock A. Hudson
|
|
|
Boise Municipal Code 4-05-32- Code Violation Not To Be Retained. NEC 110.26(F)- Dedicated equiptment space, area directly above and below is dedicated equiptment space. Gas meter is located directly below existing location. NEC 394.12- Concealed Knob and Tube Wiring, uses not permitted. (5)- Hollow spaces of walls, ceilings and attics where such spaces are insulated by loose, rolled, or foamed in place insulating material that envelopes conductors. This is a fire hazard.
|
Conference | 6/20/2013 | 6/21/2013 | 6/21/2013 | P | DONE |
Rock A. Hudson
|
|
|
Please call me when on way. Thanks, Clay ###-#### Phone #: ###-#### >> Inspection requested via web by Clay Discussed relocating service due to gas meter located directly below present location, overhead service conductors clearance over alley subject to truck traffic, and knob and tube wiring that exists in house that has insulation installed around conductors
|
Issue PAID IN FULL permit | | | 6/20/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/20/2013 | | DONE |
|
|
|
This permit was created on the web by Clay Morgan
|