Permit Information
Permit NumberELE13-01671
StatusFinaled
Name BICANDI ELECTRIC LLC
Site Address 2105 N 21ST ST
Project Name 
Customer Number989-8226
ePlanReviewNo
Description
Electrical Permit - New: New house
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/10/201312/11/201312/11/2013APASS
DetailsRock A. Hudson
Garage code is 6767 Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Final ok
Final10/18/201310/18/201310/18/2013PFAIL
DetailsRock A. Hudson
Garage code is 6767, also key is in front outlet. Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 406.5- Receptical face plates shall be installed. Garage
210.8- Receptical located with in 6' of sink shall have GFCI protection.
210.52- 2' wall space in bed shall have receptical outlet installed.
314.16- Boxes shall be of sufficient size to provide space for all conductors. Island.
Rough-In Permanent Service6/28/20137/1/20137/1/2013APASS
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
Rough in ok cover p/s u/g n ok
Final6/28/20137/1/20136/28/2013ACANC
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Inspection cancelled from web by: TOM BICANDI
Rough-In Permanent Service6/28/20136/28/20136/28/2013AFAIL
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
300.4- NM cable shall be secured at least 1 1/4" from surface of framing member.
334.30 NM cable shall be secured with in 12" of bath fan j-box.
314.4- Metal boxes shall be grounded and bonded.
250.112- non current carrying metal parts shall be grounded.
Issue PAID IN FULL permit  6/28/2013 DONE
Payment received via Govolutions
Application received  6/28/2013 DONE
This permit was created on the web by TOM BICANDI