Final | 1/13/2014 | 1/14/2014 | 1/14/2014 | A | PASS |
Bob Reichert
|
|
|
call before // Kevin Phone #: ###-#### ok final
|
Electrical Rough-In | 10/16/2013 | 10/17/2013 | 10/17/2013 | A | PASS |
Rock A. Hudson
|
|
|
KEVIN Phone #: ###-#### Sun room rough in ok cover
|
Rough-In Permanent Service | 9/24/2013 | 9/25/2013 | 9/25/2013 | A | FAIL |
Rock A. Hudson
|
|
|
call before to make sure he is there // Kevin (alt number ###-####) Phone #: ###-#### 334.30- NM cable shall be supported so not to damage cable at inervals not exceeding 4 1/2'. 334.30 (A)- NM cable shall be secured with in 12" of box with clamp or 8" with out. 300.4 Where subject to physical damage NM cable shall be protected when ran through bored or notched studs when hole is less than 1 1/4" from stud surface. 300.4- Abrasion protection shall be provided where NM cable enters metal boxes.
|
Conference | 7/26/2013 | 7/29/2013 | 7/29/2013 | A | DONE |
Rock A. Hudson
|
|
|
kevin Phone #: ###-#### Discussed Wiring of addition, and refeeding existing circuits, arc fault requirements.
|
Application received | | | 6/28/2013 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/28/2013 | | DONE |
|
|
|
|