Final | 10/21/2013 | 10/21/2013 | 10/21/2013 | P | PASS |
Daryl DeGrange
|
|
|
remodel part of job complete, final for permit ok
|
Final | 10/16/2013 | 10/16/2013 | 10/16/2013 | P | FAIL |
Daryl DeGrange
|
|
|
The home should be unlocked, if not this is the CODE 6417 Phone #: ###-#### >> Inspection requested via web by Stephen Kren NEC 230(A)(2) Service disconnecting means shall not be installed in barhrooms B.C.C 04-05-31 Distribution panels shall not be installed in a bathroom,shower room, toilet room
|
Electrical Rough-In | 9/24/2013 | 9/25/2013 | 9/25/2013 | A | PASS |
Daryl DeGrange
|
|
|
Installing smoke detectors in the (2) basement bedrooms below the master bedroom Phone #: ###-#### >> Inspection requested via web by Stephen Kren rough-in ok
|
Electrical Rough-In | 9/19/2013 | 9/20/2013 | 9/20/2013 | P | PASS |
Daryl DeGrange
|
|
|
Please call for any questions, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren corrections done, rough-in ok cover
|
Electrical Rough-In | 9/18/2013 | 9/19/2013 | 9/19/2013 | A | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Stephen Kren NEC 314.29 Attic junction boxes shall be located where acccessible
|
Electrical Rough-In | 9/18/2013 | 9/18/2013 | 9/18/2013 | A | FAIL |
Doug A Poedy
|
|
|
the (2) corrections have been done, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren. Please schedule conference.
|
Electrical Rough-In | 9/17/2013 | 9/17/2013 | 9/17/2013 | P | FAIL |
Rock A. Hudson
|
|
|
We installed new wiring in the garage and mstr bedroom, they are both ready for insp. any questions please call, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren 300.4-NM cable shall be protected from physical damage when ran through notched studs or whole is less than 1/4" from stud surface. 314.23, 334.30- J-box above master bath door shall be secured and NM cable shall before entering box.
|
Permanent Service | 8/28/2013 | 8/29/2013 | 8/29/2013 | A | PASS |
Daryl DeGrange
|
|
|
ACCESS CODE - 6417, we are wanting to get the power turned on to supply power to a couple of circuits not affected by the fire, I have a note labeled by the panel instructing that the electrician are the only ones allowed to turn on any breakers, please call me for any questions, my cell is ###-####, thanks, Terry W. Code - 6417 Phone #: ###-#### >> Inspection requested via web by Stephen Kren A/C unit will be moved today, p/s o/h rec ok
|
Permanent Service | 8/22/2013 | 8/23/2013 | 8/23/2013 | A | NH |
Daryl DeGrange
|
|
|
This inspection needed is just for the service, we are trying to get the power turned on so we can provide temp power, we will be scheduling for a rough inspection further down the road, any questions please let me know, thanks. Phone #: ###-#### >> Inspection requested via web by Stephen Kren no access
|
Issue PAID IN FULL permit | | | 8/22/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/22/2013 | | DONE |
|
|
|
This permit was created on the web by Stephen Kren
|