Permit Information
Permit NumberELE13-02486
StatusFinaled
Name SUPERIOR ELECTRICAL CONTRACTORS
Site Address 2203 S MANITOU AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: new build 11-14-13 space heating is electrical radiant heat
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/5/20141/6/20141/6/2014APASS
DetailsBob Reichert
Ryan is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut corrections made, ok final, house only, not pool
Final1/2/20141/2/20141/2/2014PCANC
DetailsBob Reichert
Ryan is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut talked to contractor, he asked to cancel pm inspection today
Final1/2/20141/2/20141/2/2014ACANC
DetailsBob Reichert
Ryan is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Inspection cancelled from web by: Chris Chesnut
Final12/31/201312/31/201312/31/2013PFAIL
DetailsBob Reichert
Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, too many items too list, some items: dead outlets in garage,washer not on gfci,fan box open at front door, bath gfci's won't set, kitchen plugs dead, outlet spacing in kitchen not per code, dining room outlet dead, hall receptacle dead, no light switches for up lights in big room, loose bath receptacle down bath, service riser shall be strapped, breakers labelled, ground bar for intersystem bond shall be installed, if balcony over 20 sq feet, shall add outlet
Final12/30/201312/30/201312/30/2013PNR
DetailsBob Reichert
Final. Ryan is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut still wiring lights, switches and outlets, will recall when done
Electrical Rough-In11/14/201311/15/201311/15/2013APASS
DetailsBob Reichert
floor heat Phone #: ###-#### >> Inspection requested via web by Chris Chesnut ok cover floor heat
Electrical Rough-In11/14/201311/14/201311/14/2013PNR
DetailsBob Reichert
floor heat Ryan Weiderich ###-#### Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, told to recall when other room heat laid
Issue PAID IN FULL permit  9/12/2013 DONE
Payment received via Govolutions
Fees Due Hold9/12/2013 9/12/2013 DONE
Details
Rough-In Permanent Service9/11/20139/11/20139/11/2013PPASS
DetailsBob Reichert
Chris Phone #: ###-#### ri ok, p/s u/g n ok
Rough-In Permanent Service9/10/20139/11/20139/11/2013AFAIL
DetailsBob Reichert
Cj is contact. Thank you. Phone #: ###-#### >> Inspection requested via web by Chris Chesnutcalled, left correction notice, NEC 680.25 feeder to panelboard shall be run in raceway if supplying branch circuits for pool equipment, 314.17(C) shall staple nm cable within 8" of box, 314.20 boxes shall be flush with finished surface in combustible walls, BCC shall change permit to minimum 25 rooms and add for pool
Rough-In Permanent Service9/9/20139/10/20139/10/2013AFAIL
DetailsBob Reichert
cj is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, shall provide damp rating for sub-panel in pool room, shall provide feeders per NEC 680, shall provide corrected room count for permit (minimum 25 rooms), including pool, shall provide flush mounted outdoor boxes, shall staple nm cable, will recall, talked about pool lighting
Issue PAID IN FULL permit  9/9/2013 DONE
Payment received via Govolutions
Application received  9/9/2013 DONE
This permit was created on the web by Chris Chesnut