Case Summary (ELE) | | | 9/19/2016 | | DONE |
|
|
|
|
Final | 2/17/2014 | 2/18/2014 | 2/18/2014 | A | PASS |
Rock A. Hudson
|
|
|
garage code 8898 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey final ok corrections made
|
Final | 2/13/2014 | 2/14/2014 | 2/14/2014 | A | FAIL |
Bob Reichert
|
|
|
garage code 88989 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, left correction notice, NEC 210.52(B) pantry shall have gfci receptacles, 210.52(A)(2) mbr wall space over 2' shall have receptacles, 250.94 shall provide intersystem bond bar, 352.30 shall strap pvc within 3' of termination, NOTE: basement room has no receptacles, provide switch cover screws
|
Electrical Rough-In | 10/29/2013 | 10/29/2013 | 10/29/2013 | P | PASS |
Rock A. Hudson
|
|
|
Tennis light, pool equipment Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Pending pull point at end of lower wall. Rough in ok cover
|
Issue PAID IN FULL permit | | | 10/29/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Final | 10/22/2013 | 10/23/2013 | 10/23/2013 | A | FAIL |
Bob Reichert
|
|
|
Ran conduit for pool and tennis light Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, shall include pool and tennis court on permit, NEC 300.5 shall bury conduit correct depth, 352.26 shall not be over 360 degree bend in raceway, 300.11 shall not use raceway as means of support
|
Rough-In Permanent Service | 10/10/2013 | 10/10/2013 | 10/10/2013 | A | PASS |
Rock A. Hudson
|
|
|
If you could call me in advance so I can bring my ladder that would be great. Thanks Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 10/8/2013 | 10/8/2013 | 10/8/2013 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey 300.4 Bored holes less than 1 1/4" from stud surface shall be protected from physical damage. NM cable and low volt shall be protected. 210.52- Receptical outlets shall be installed so that no point measured along floor line is more than 6' from outlet. Master bed and family rm. 210.52- Receptical outlet shall be installed with in 6' of door opening measured along floor line. Down bed pocket door to bath. * Out patio ceilings covered prior to inspection.
|
Issue PAID IN FULL permit | | | 10/8/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/7/2013 | | DONE |
|
|
|
This permit was created on the web by Neal Rumsey
|