Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberELE13-02994
StatusFinaled
Name YOUNG REBECCA A
Site Address 4937 N COLLISTER DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/3/20152/4/20152/4/2015APASS
DetailsCevyn Recla
Lori Phone #: ###-####
corrections made, final oK
Final1/30/20152/3/20152/3/2015PFAIL
DetailsCevyn Recla
Lori Phone #: ###-####
406.12 A Dwelling unit, tamper resistant receptacles required
Electrical Rough-In1/2/20151/2/20151/2/2015PPASS
DetailsCevyn Recla
Lori Phone #: ###-####
corrections have been made to kitchen circuits. Owners are going to hire a contractor for service change to allow for new circuits to be added to meter main service. will check ground make up for kithchen outlets at service inspeciton time.. Kitchen OK to cover
Electrical Rough-In12/30/201412/31/201412/31/2014AFAIL
DetailsRock A. Hudson
Lori-calling in for homeownerplease call meet-Phone #: ###-#### 210.52- Kitchen counter top receptical outlets shall be fed by a minimum of 2 20 amp 120 volt circuits. Small appliance circuits shall be dedicated to counter top recepticals or appliances, no lighting. 2nd circuit required for counter top outlets. 1 circuit for dishwasher/ disposal.
300.4- NM cable shall be secured1 1/4" from framing surface. Where bored holes are less than 1 1/4" from surface nail plate shall be used.
310.15- All 20 amp 120 volt circuits shall be minimum of 12-2 NM cable from start of circuit to end of circuit.
Meter base has 30/40 quad on 15 and 20 amp wire.
ELE-Request for Extension12/16/201412/17/201412/17/2014APASS
DetailsCevyn Recla
Mike Phone #: ###-####
Spoke to homeowner, they are moving forward with the renovation, and plan to have RI ready to inspect in near future. Extension given.
Conference10/28/201310/28/201310/28/2013PDONE
DetailsRock A. Hudson
After 1:30 please - Mike Phone #: ###-#### Discussed required receptical spacing and circuits for kitchen remodel, and inspection process.
Issue PAID IN FULL permit  10/25/2013 DONE
Payment received via Govolutions
Issue PAID IN FULL permit  10/25/2013 DONE
DetailsBarbara Stitt
Application received  10/25/2013