Permit Information
Permit NumberELE13-03141
StatusFinaled
Name BENDER ELECTRIC SERVICES
Site Address 406 S VICTORIA DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: New 12 unit multi family dwelling
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice7/29/20147/29/20144/17/2015 DONE
DetailsRock A. Hudson
This permit finaled on the web by kendall bender
Final7/28/20147/29/20147/29/2014APASS
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by kendall bender Final ok
Final7/25/20147/28/20147/28/2014AFAIL
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by kendall bender
314.20- Boxes set back in tile more than 1/4" chall have spark rings.
408.4 house panel, panel schedule shall be complete.
110.3- open neutral and hot neutral reversed in 3 locations.
422.30- Where water heater are not with in sight of panels provide lock out for disconnecting means.
Electrical Rough-In6/13/20146/13/20146/13/2014PPASS
DetailsRock A. Hudson
Parking lot ug Phone #: ###-#### >> Inspection requested via web by kendall bender Parking lot and landscape rough in ok cover
Electrical Rough-In4/23/20144/23/20144/23/2014PPASS
DetailsBob Reichert
ok cover dropped ceilings 8 units, 1st and second floor only
Electrical Rough-In3/25/20143/26/20143/26/2014APASS
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by kendall bender corrections made, ri ok
Permanent Service3/26/20143/26/20143/26/2014APASS
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by kendall bender p/s u/g n ok, 13 meters req'd
Electrical Rough-In3/24/20143/24/20143/24/2014PFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by kendall bender shall provide pipe protection per 110.26 (F), not 6' over sub-panels, shall label meters
Electrical Rough-In3/14/20143/17/20143/17/2014APART
DetailsBob Reichert
Partial roughin for fire barrier. Phone #: ###-#### >> Inspection requested via web by kendall bender shall repair cut wiring, nailplates, add boxes, firewall ok behind service only ok vover
Permanent Service3/14/20143/17/20143/17/2014ANR
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by kendall bender met contractor, shall post available fault current at service, shall label main and feeder disconnects
Electrical Rough-In11/9/201311/12/201311/12/2013APASS
DetailsBob Reichert
Ufer inspection Phone #: ###-#### >> Inspection requested via web by kendall bender ok pour concrete encased electrode
Issue PAID IN FULL permit  11/9/2013 DONE
Payment received via Govolutions
Application received  11/9/2013 DONE
This permit was created on the web by kendall bender