Final | 1/31/2014 | 1/31/2014 | 1/31/2014 | P | PASS |
Bob Reichert
|
|
|
Clyde Phone #: ###-#### corrections made, ok final
|
Final | 1/30/2014 | 1/30/2014 | 1/30/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Clyde Phone #: ###-#### 410.10(A)- Fan/light combo rated for shower if GFCI protected, GFCI located in up hall and pantry. Need to confirm. 408.38-Panel cover shall be securely fastened. 314.23- Receptical outlet located at end of peninsula shall be securely fastened
|
Electrical Rough-In | 12/4/2013 | 12/4/2013 | 12/4/2013 | P | PASS |
Bob Reichert
|
|
|
UG pipe insp// Clyde Phone #: ###-#### ok cover u/g house to garage only
|
Electrical Rough-In | 11/22/2013 | 11/22/2013 | 11/22/2013 | P | FAIL |
Bob Reichert
|
|
|
underground piping for garage please-Clyde Phone #: ###-#### called, left message, no conduit visible in pot holes, shall recall
|
Electrical Rough-In | 11/18/2013 | 11/19/2013 | 11/19/2013 | A | PASS |
Bob Reichert
|
|
|
Clyde Phone #: ###-#### ok cover garage only
|
(F) Reprint permit | | | 11/18/2013 | | DONE |
|
|
|
|
Electrical Rough-In | 11/12/2013 | 11/12/2013 | 11/12/2013 | P | PASS |
Bob Reichert
|
|
|
clyde Phone #: ###-#### ri ok except garage
|
Permanent Service | 11/12/2013 | 11/12/2013 | 11/12/2013 | P | PASS |
Bob Reichert
|
|
|
clyde Phone #: ###-#### p/s u/g n ok
|
Application received | | | 11/12/2013 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 11/12/2013 | | DONE |
|
|
|
|