Permit NumberELE13-03185
StatusFinaled
Name BENCHMARK ELECTRIC CO
Site Address 3941 E BARBER DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: New residential home/// per phone call from Krista at Benchmark added 4 rooms to permit 11/14/13 leg
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/24/20143/24/20143/24/2014PPASS
DetailsBob Reichert
Please re-inspect, issues fixed.
Thank you, >> Inspection requested via web by Rhonda Zamagni corrections made, ok final
Final3/20/20143/21/20143/21/2014AFAIL
DetailsBob Reichert
>> Inspection requested via web by Rhonda Zamagni called, left correction notice, NEC 210.52(D) bath receptacle shall be by sink, not in cabinet, 110.3(B) shall install receptacles per instructions- left of fireplace h&n reversed, upper bedroom south and center have open grounds
Electrical Rough-In11/14/201311/15/201311/15/2013APASS
DetailsBob Reichert
Thank you! Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni corrections made, ri ok
Electrical Rough-In11/14/201311/14/201311/14/2013PFAIL
DetailsRock A. Hudson
Any discrepancies with room counts or other please call our office asap so it can be corrected. They need the service inspection to pass today please.
Thank you very ###-#### >> Inspection requested via web by Rhonda
Zamagni 334.15(B)- NM cable shall be protected from physical damage.
334.30- NM cable shall be secred with in 12" of boxes.
334.30- NM cable shall not be secured less than 1 1/4" from surface of framing member.
300.4- NM cable shall be protected from physical damage when ran through bored holes that are less than 1 1/4" from surface of framing member.
314.17- Unused openings shall be closed.
Permanent Service11/14/201311/14/201311/14/2013PPASS
DetailsRock A. Hudson
Any discrepancies with room counts or other please call our office asap so it can be corrected. They need the service inspection to pass today please.
Thank you very much, p/s u/g n ok
Krista Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni
Issue PAID IN FULL permit  11/14/2013 DONE
Payment received via Govolutions
Application received  11/14/2013 DONE
This permit was created on the web by Rhonda Zamagni