Final | 12/15/2014 | 12/17/2014 | 12/17/2014 | A | PASS |
Cevyn Recla
|
|
|
Call prior to going Phone #: 2088661213 >> Inspection requested via mobile web by Todd Nelson corrections made, final ok
|
Final | 12/8/2014 | 12/11/2014 | 12/11/2014 | A | FAIL |
Cevyn Recla
|
|
|
Phone #: 2088661213 >> Inspection requested via mobile web by Todd Nelson spoke with owner about corrections romex must be secured within 12 inches of box permanently attached appliances shall have means of disconnect, ovens, d/w, rangehood, micro romex shall be subject to damage, provide cover
|
Electrical Rough-In | 1/10/2014 | 1/13/2014 | 1/13/2014 | A | PASS |
Daryl DeGrange
|
|
|
call 1/2 hr before to meet // Todd Phone #: ###-#### rough-in ok cover kitchen and bathroom areas, Ask homeowner to remove bundled NM cables (homeruns) from 2in PVC to panel in basement
|
Conference | 12/27/2013 | 12/30/2013 | 12/30/2013 | A | DONE |
Rock A. Hudson
|
|
|
Todd Nelson Phone #: ###-#### See notes from 12-27 13
|
Conference | 12/27/2013 | 12/27/2013 | 12/27/2013 | P | DONE |
Rock A. Hudson
|
|
|
Discussed kitchen counter top recepticals, dedicated circuits, stapling and lghting.
|
Application received | | | 12/20/2013 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 12/20/2013 | | DONE |
|
|
|
|