Final | 6/18/2014 | 6/18/2014 | 6/18/2014 | A | PASS |
Rock A. Hudson
|
|
|
Call Dylan ###-#### for access. Half hour ahead will be great. Thank you Phone #: ###-#### >> Inspection requested via web by daniel bibikov Final ok
|
Final | 6/16/2014 | 6/16/2014 | 6/16/2014 | P | FAIL |
Rock A. Hudson
|
|
|
call dylan half hour prior for access ###-####. thank you Phone #: ###-#### >> Inspection requested via web by daniel bibikov 406.3(D)- Grounding type receptical outlets installed on ungrounded circuit shall have GFCI protection or be changed to 2-wire recepticals. 2 receptical outlets on wall opposite sink in kitchenette not working.
|
Final | 6/11/2014 | 6/12/2014 | 6/12/2014 | A | NH |
Bob Reichert
|
|
|
dillon Phone #: ###-####called, will re-schedule
|
Final | 6/11/2014 | 6/11/2014 | 6/11/2014 | A | NH |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov left card
|
Final | 6/9/2014 | 6/10/2014 | 6/10/2014 | A | CANC |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Inspection cancelled from web by: daniel bibikov
|
Electrical Rough-In | 2/26/2014 | 2/26/2014 | 2/26/2014 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough in ok for cover
|
Electrical Rough-In | 2/24/2014 | 2/25/2014 | 2/25/2014 | A | FAIL |
Rex Boyles
|
|
|
Addition to the house and sub panel Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 334.30-romex or nm cable shall be secured supported within 12" of every box. 210.52-(D)- at least 1 receptacle shall be installed within 3 feet of outside edge of each basin in bath. 300.4(A)- NM cable shall be protected from physical damage. (nailplates) 314.16-boxes shall be of suffecient size to provide free space for all enclosed conductors.
|
Issue PAID IN FULL permit | | | 2/17/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/17/2014 | | DONE |
|
|
|
This permit was created on the web by daniel bibikov
|