Final | 4/30/2014 | 4/30/2014 | 5/1/2014 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt Contractor to add receptical outlet to leftof oven to satify 210.52. rest of house ok. Final ok
|
Final | 4/30/2014 | 4/30/2014 | 4/30/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt 410.16(A)(1)- Luminaires located in closet shall have a totally enclosed lamps. 410.16(C)(1)- Incandescent luminaire shall clear storage shelf by minimum of 12". BCC- High efficiency lamps shall be install in at leat 50% of perminantly installed light fixtures. 210.52(C)(1)- Receptical outlets shall be installed so that no point measured along wall line is more than 24" to receptical outlet serving counter top.
|
Rough-In Permanent Service | 2/19/2014 | 2/19/2014 | 2/19/2014 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt r/i ok to cover p/s u/g n ok
|
Issue PAID IN FULL permit | | | 2/19/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/19/2014 | | DONE |
|
|
|
This permit was created on the web by John VanZandt
|