Final | 11/11/2014 | 11/12/2014 | 11/12/2014 | A | PASS |
Rex Boyles
|
|
|
call for access if not open Phone #: ###-#### Inspection requested via web by shane vigil final ok
|
Final | 11/5/2014 | 11/6/2014 | 11/6/2014 | P | FAIL |
Rex Boyles
|
|
|
back slider open. Phone #: ###-#### Inspection requested via web by shane vigil Loose receptacles in kitchen and upst. bath. 406.11-in all areas listed in 210.52 all 125 volt receptacles shall be tamper resistant.ok not to have tamper resistant in area of house not worked on. 314.20-face of box shall be 1/4inch or less to finsh surface(kitchen backsplash) or use box extensions. 210.12(B)-AFCI protection required in all bedrooms. ok not to have afci in old existingbdrms. 210.52(E)(1)-at least one receptacle outlet accessable from grade level required at back of dwelling.ok not to install in front. 210.8(A)(7)- GFCI protection required where receptacles are installed within 6 foot of sink (laundry room). 410.10(A)-recessed fixture in shower not rated for wetlocation.basement bdrm. closet fixture has no globe.
|
Electrical Rough-In | 5/21/2014 | 5/22/2014 | 5/22/2014 | A | PASS |
Bob Reichert
|
|
|
call for key location Phone #: ###-#### >> Inspection requested via web by shane vigil corrections made, ri ok
|
Electrical Rough-In | 5/21/2014 | 5/21/2014 | 5/21/2014 | A | FAIL |
Rex Boyles
|
|
|
ELE-INSPECTOR 334.30 secure nm cable min. every 4 1/2 feet above sub-panel in hall. 300.4D 11/4 min to nm cable from edge of framing. under subpanel and 1/0ser in kitchen. Exhaust fan not installed and waterbond ground needs to be connected.
|
Permanent Service | 5/5/2014 | 5/6/2014 | 5/6/2014 | A | PASS |
Rex Boyles
|
|
|
Service only, rough in and sub panel to be done after. Phone #: ###-#### >> Inspection requested via web by shane vigil p/s o/h rec ok please use "rigid" strap for rigid riser when you get the chance
|
Issue PAID IN FULL permit | | | 5/5/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/5/2014 | | DONE |
|
|
|
This permit was created on the web by shane vigil
|