Final | 11/10/2014 | 11/12/2014 | 11/12/2014 | P | PASS |
Cevyn Recla
|
|
|
as early PM as possible please // Mark Phone #: ###-#### Corrections made. FInal OK
|
Final | 11/7/2014 | 11/10/2014 | 11/10/2014 | P | FAIL |
Cevyn Recla
|
|
|
Mark Phone #: ###-#### Art. 100, disconnecting means for water heater 406.12A Tamper resistant receptacles required for dwelling unit 210.52B2 Kitchne small applinance circuit can not feed outdoor receptacle
|
Permanent Service | 10/1/2014 | 10/2/2014 | 10/2/2014 | A | PASS |
Rock A. Hudson
|
|
|
Mark Phone #: ###-#### p/s o/h n ok
|
Electrical Rough-In | 9/12/2014 | 9/15/2014 | 9/15/2014 | A | PASS |
Rock A. Hudson
|
|
|
Mark-woluld like later in the AM if posssible Phone #: ###-#### Clamping connector shall be installed on back of meter for SER entrance to can. Addition rough in ok cover
|
Conference | 9/11/2014 | 9/11/2014 | 9/11/2014 | P | DONE |
Rex Boyles
|
|
|
mark Phone #: ###-#### discuss 400 amp meter with bypass. Told mark to confirm its ok. discuss bending 300 alum in 2x6 wall, discuss 300 alum in raceway thru attic ,is ok
|
Conference | 8/28/2014 | 8/29/2014 | 8/29/2014 | A | DONE |
Rex Boyles
|
|
|
mark Phone #: ###-#### discuss 400 amp service and circuitry
|
Electrical Rough-In | 8/15/2014 | 8/18/2014 | 8/18/2014 | A | CANC |
Rock A. Hudson
|
|
|
Actually wants a conference----Mark Phone #: ###-#### Conference requested
|
Conference | 8/18/2014 | 8/18/2014 | 8/18/2014 | P | DONE |
Rock A. Hudson
|
|
|
Actually wants a conference----Mark Phone #: ###-#### Discussed minimum kitchen counter top circuits and receptical layout,service grounding, direct burial depth, dedicated bath receptical circuit. overhead service entrance clearances.
|
Application received | | | 5/9/2014 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 5/9/2014 | | DONE |
|
|
|
|