Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE14-01242
StatusFinaled
Name S K ELECTRIC
Site Address 12600 W USTICK RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: wiring of 8 plex
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice3/31/20153/31/201512/30/2015 DONE
DetailsRock A. Hudson
This permit finaled on the web by Shaun Kirkman
Final3/31/20153/31/20153/31/2015APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Shaun Kirkman No card posted. Final ok
Final3/4/20153/4/20153/4/2015AFAIL
DetailsBob Reichert
Phone #: ###-#### Inspection requested via web by Shaun Kirkman called, left correction notice, NEC 110.3 bath gfci shall be wired correctly, unit #4, 110.3(B) shall finish patio gfci unit 4l, 210.52 shall provide outlet spacing upper bedroom, unit 4l, 430 shall provide disconnect switches for disposals all units
Electrical Rough-In9/12/20149/12/20149/12/2014APASS
DetailsDaryl DeGrange
please inspect conduit for future post light Thanks Shaun Phone #: ###-#### Inspection requested via web by Shaun Kirkman rough-in ok cover trench (Parking lot lighting)
Rough-In Permanent Service7/25/20147/25/20147/25/2014APASS
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in p/s u/g n eight plex
Conference7/10/20147/10/20147/10/2014ADONE
DetailsDaryl DeGrange
please call me half an hour before conference thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Discussed NEC 110.26 foreign systems installed directly above the dedicated space reserved for electrical equipment, installing gutters and or relocating
Electrical Rough-In7/10/20147/10/20147/10/2014PPASS
DetailsDaryl DeGrange
please call me half an hour before conference thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Rough-in ok cover upper lofts areas.
Rough-In Permanent Service7/8/20147/8/20147/8/2014AFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman called contractor, too many violations to write correction notice-items seen are: support ser, repair ser, no foreign systems over sub-panels, staple nm, use nailplates, provide loft access when built, post job id sticker, post address, post esc cigns
Conference5/14/20145/14/20145/14/2014PDONE
DetailsDaryl DeGrange
please call me to schedule time to meet on site thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Discussed elecrtrical requirements for missing concrete encased electrode, receptacle layout for spiral staircase
Issue PAID IN FULL permit  5/14/2014 DONE
Payment received via Govolutions
Application received  5/14/2014 DONE
This permit was created on the web by Shaun Kirkman