Final | 12/28/2016 | 12/28/2016 | 12/28/2016 | P | PASS |
Eric Story
|
|
|
dave Phone #: ###-#### Corrections fixed final ok
|
Final | 9/7/2016 | 9/8/2016 | 9/8/2016 | A | FAIL |
Rock A. Hudson
|
|
|
call dave for access ###-#### Phone #: ###-#### Inspection requested via web by danny perrine 210.52- A receptacle outlet shall be located at end of peninsula in kitchen. 300.15- Washer wire hanging in basement shall be secured and installed in a box and trimmed. 334.30- 10-3 for dryer shall be secured and box mounted. 400.8- Extension cord feeding washer shall be removed. 408.4- Panel covers shall be installed and labelled.
|
Electrical Rough-In | 8/8/2016 | 8/8/2016 | 8/8/2016 | P | PASS |
Rock A. Hudson
|
|
|
kitchen area. Please call Dave 30 min before ###-#### Phone #: ###-#### Inspection requested via web by danny perrine Kitche remodel rough in ok cover
|
Electrical Rough-In | 1/22/2015 | 1/23/2015 | 1/23/2015 | A | PASS |
Rex Boyles
|
|
|
call for access bathroom and living room are finally finished ready for rough in inspection Phone #: ###-#### Inspection requested via web by danny perrine r/i ok
|
Rough-In Permanent Service | 6/30/2014 | 7/3/2014 | 7/3/2014 | P | CANC |
Rex Boyles
|
|
|
Ruffin portion of the remodel should be finished service chance scheduled with Idaho Power disconnected 9 a.m. I anticipate being ready for inspection by noon so we can get re energized please call with any questions or if there''s any reason we won''t be able to get an inspection with the holiday weekend i want to make sure we get the power back on the homeowner Phone #: ###-#### >> Inspection requested via web by danny perrine needed p/s
|
Permanent Service | 7/3/2014 | 7/3/2014 | 7/3/2014 | P | PASS |
Rex Boyles
|
|
|
Ruffin portion of the remodel should be finished service chance scheduled with Idaho Power disconnected 9 a.m. I anticipate being ready for inspection by noon so we can get re energized please call with any questions or if there''s any reason we won''t be able to get an inspection with the holiday weekend i want to make sure we get the power back on the homeowner Phone #: ###-#### >> Inspection requested via web by danny perrine p/s o/h rec ok
|
Issue PAID IN FULL permit | | | 6/19/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/19/2014 | | DONE |
|
|
|
This permit was created on the web by danny perrine
|