Permit Information
Permit NumberELE14-01910
StatusFinaled
Name GOLDEN ELECTRIC
Site Address 1509 N 7TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: remodel/new construction. electrical work includes all new wiring and 200 amp service in residence. 200 amp service in garage will be completed when garage is complete
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/14/20151/14/20151/14/2015PPASS
DetailsCevyn Recla
Key is in the same location

Call Tim if needed

Thank you Phone #: ###-#### Inspection requested via web by John Harvey
no inspection record of floor heat under tile, cable that can be seen is listed product
corrections made, final OK
Final1/12/20151/13/20151/13/2015AFAIL
DetailsCevyn Recla
Call Tim if any problems

Key is above the small window on the front porch Phone #: ###-#### Inspection requested via web by John Harvey
left notice with building contractor
210.8A 2 GFI protection required, all receptacles in garage
210.8A7 GFI protection require all receptacles within 6 foot of sink
334.12 NM calbe not permitted in wet locations
422.31 Disconnecting means required for all permanently installed appliances
210.52 C 3 Penninsula receptacle required
356.30 LFNC shall be secured within 12 inches of boxes
408.4 Circuit directory shall be legibly marked
110.3 B Installation and use, items shall be installed according to instructions, fllor heat thermostat not functioning, could not test GFI
Electrical Rough-In12/24/201412/26/201412/26/2014APASS
DetailsCevyn Recla
corrections made, garage r/i ok to cover
Electrical Rough-In12/23/201412/24/201412/24/2014AFAIL
DetailsCevyn Recla
Garage rough in only

Tim is general contractor. Contact if needed

Phone #: ###-#### Inspection requested via web by John Harvey
left voicemail at number provided
334.30 NM shall be secured by staple, cable tie, strap, or similar fitting designed not to damage cable
3334.80 ampacity of nm, bundling of romex through holes, no more than six current carrying conductors allowed
250.68 A grounding electrode connection shall be accessible
300.4 NM through bored holes shall have protection where hole is less than 1 1/4 inch from framing member edge
352.24 Rigid PVC bends shall be made so conduit is not damaged
BCC, all items shall be ready for inspection type that is being made, there are romex and box hanging out of wall.
Final11/7/201411/7/201411/7/2014PCANC
DetailsCevyn Recla
Tim-perm. service for garage Phone #: ###-####

Wrong inspection called in
Permanent Service11/7/201411/7/201411/7/2014PPASS
DetailsCevyn Recla
Tim-perm. service for garage Phone #: ###-####

PS, OH, N , OK
Change Status to I  11/7/2014 DONE
DetailsCandy A. Nichols
no final has been done, still have inspections that need to be done on this permit
Temporary Service9/12/20149/12/20149/12/2014PPASS
DetailsRex Boyles
Temp service to prepare for garage demo. Contact builder at above number. Phone #: ###-#### Inspection requested via web by John Harvey t/s o/h n ok (existing service drop might not be long enough)
Electrical Rough-In7/14/20147/15/20147/15/2014PPASS
DetailsRex Boyles
John is out of town. House is open. Call Tim if there are any issues


Phone #: ###-#### >> Inspection requested via web by John Harvey r/i ok
Issue PAID IN FULL permit  7/14/2014 DONE
Payment received via Govolutions
Application received  7/14/2014 DONE
This permit was created on the web by John Harvey