Permit Information
Permit NumberELE14-02086
StatusFinaled
Name PHILLIPS JORDAN M
Site Address 11694 W USTICK RD
Project NameADU
Customer Number 
ePlanReviewNo
Description
Permit to rewire home to current code and set up service
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/4/201411/4/201411/4/2014PPASS
DetailsRock A. Hudson
Nikoa Phone #: ###-#### Final ok
Final10/27/201410/28/201410/28/2014AFAIL
DetailsDaryl DeGrange
Nikoa Phone #: ###-#### NEC 408.4 Panel directory not complete NEC 406.8(B)(1) GFCI receptacle for A/C unit requires weather resistant listing (WR) Double duplex receptacles in family room (grounging type) without equipment grounding conductor require GFCI protection. NEC 110.26 Clearance for A/C disconnect
Electrical Rough-In8/6/20148/7/20148/7/2014APASS
DetailsDaryl DeGrange
Jordan Phone #: ###-#### Rough-in ok cover
Permanent Service8/7/20148/7/20148/7/2014APASS
DetailsDaryl DeGrange
Jordan Phone #: ###-#### p/s o/h n ok
Electrical Rough-In8/5/20148/6/20148/5/2014AFAIL
DetailsDaryl DeGrange
Jordan Phone #: ###-#### BCC and Idaho Power requirement Overhead service raiser, shall be 2 in.IMC if point of attachement NEC 250.96 Bonding of enclosures NEC 312.5(c) Cables shall be secured to cabnets, cutout boxes at entry NEC 200.6 Means of identifying grounded conductors
Conference7/30/20147/31/20147/31/2014ADONE
DetailsDaryl DeGrange
Doug wants to meet as well, please call him for appoint - Jordan Phone #: ###-#### Discussed with home owner elecetrical requirements for relocated single fmily dwellings.
Application received  7/30/2014  
Issue PAID IN FULL permit  7/30/2014 DONE