DOC - Permit Expired | 2/1/2019 | 2/1/2019 | 2/1/2019 | P | PASS |
Daryl DeGrange
|
|
|
No activity within 180 days. This permit is EXPIRED. A new permit is required to complete this job.
|
Permanent Service | 9/29/2014 | 9/29/2014 | 9/29/2014 | P | PASS |
Daryl DeGrange
|
|
|
The access code is 7971, any questions please call, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren correction done, p/s u/g rec ok
|
Permanent Service | 9/26/2014 | 9/26/2014 | 9/26/2014 | P | CANC |
Daryl DeGrange
|
|
|
The access code is 7971, any questions please let me know, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
|
Permanent Service | 9/26/2014 | 9/26/2014 | 9/26/2014 | P | CANC |
Daryl DeGrange
|
|
|
Any questions please let me know, thx! TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
|
Permanent Service | 9/24/2014 | 9/25/2014 | 9/25/2014 | A | FAIL |
Rock A. Hudson
|
|
|
The access code 6210, thx Phone #: ###-#### Inspection requested via web by Stephen Kren Code for lock box does not work. 250.24 Grounding Service-Supplied Alternating-Current Systems. (A) System Grounding Connections. A premises wiring system supplied by a grounded ac service shall have a grounding electrode conductor connected to the grounded service conductor, at each service, in accordance with 250.24(A)(1) through (A)(5). (1) General. The grounding electrode conductor connection shall be made at any accessible point from the load end of the overhead service conductors, service drop, underground service conductors, or service lateral to, including the terminal or bus to which the grounded service conductor is connected at the service disconnecting means
|
Permanent Service | 9/23/2014 | 9/24/2014 | 9/24/2014 | A | FAIL |
Bob Reichert
|
|
|
The access code is 6210, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren called, left message, ground rods not installed, access code not working
|
Permanent Service | 8/26/2014 | 8/27/2014 | 8/27/2014 | A | FAIL |
Daryl DeGrange
|
|
|
The Access code is 7971, any questions please let me know, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren NEC 250.56 Service requires two ground rods. Shall terminate only one neutral conductor per lug
|
Issue PAID IN FULL permit | | | 8/26/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/26/2014 | | DONE |
|
|
|
This permit was created on the web by Stephen Kren
|