Final | 10/30/2014 | 10/30/2014 | 10/30/2014 | P | PASS |
Daryl DeGrange
|
|
|
job complete, final ok
|
Permanent Service | 10/30/2014 | 10/30/2014 | 10/30/2014 | P | PASS |
Daryl DeGrange
|
|
|
correction done, p/s u/g rec ok
|
Permanent Service | 10/22/2014 | 10/23/2014 | 10/23/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Mter was off for more than 1 year. Lock box on gas meter #4907. Phone #: ###-#### Inspection requested via web by Alan Lusk 352.30 Securing and Supporting. PVC conduit shall be installed as a complete system as provided in 300.18 and shall be fastened so that movement from thermal expansion or contraction is permitted. PVC conduit shall be securely fastened and supported in accordance with 352.30(A) and (B). (A) Securely Fastened. PVC conduit shall be securely fastened within 900 mm (3 ft) of each outlet box, junction box, device box, conduit body, or other conduit termination. Conduit listed for securing at other than 900 mm (3 ft) shall be permitted to be installed in accordance with the listing. 110.12.B (B) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues. There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment such as parts that are broken; bent; cut; or deteriorated by corrosion, chemical action, or overheating.
110.26.a.1 Working spaces shall be maintained. 3 ft. clearance. Remove tomato plant.
|
Permanent Service | 10/22/2014 | 10/23/2014 | 10/22/2014 | A | CANC |
Rock A. Hudson
|
|
|
Service was off more than 1 year Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk
|
Issue PAID IN FULL permit | | | 10/22/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/22/2014 | | DONE |
|
|
|
This permit was created on the web by Alan Lusk
|