Final | 1/9/2015 | 1/9/2015 | 1/9/2015 | P | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder final ok
|
Permanent Service | 1/8/2015 | 1/9/2015 | 1/9/2015 | A | PASS |
Rex Boyles
|
|
|
Lock Box 8791 Phone #: ###-#### Inspection requested via web by Eric Schroeder p/s o/h rec ok
|
Permanent Service | 12/12/2014 | 12/15/2014 | 12/15/2014 | A | FAIL |
Cevyn Recla
|
|
|
Call Eric with questions. Lock box on back door #8791 Phone #: ###-#### Inspection requested via web by Eric Schroeder 250.53 Supplemental ground required Subpanel lugs are not rated for two conductors 250.24 Grounded conductor shall not be connected to non current carrying metal parts, grounded and grounding condutors shall be isolated from each other at subpanels Subpanel does not have a grounded conductor, yet grounded conductors are in use on line side,
|
Issue PAID IN FULL permit | | | 12/12/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/12/2014 | | DONE |
|
|
|
This permit was created on the web by Eric Schroeder
|