Final | 4/9/2015 | 4/10/2015 | 4/10/2015 | A | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt correction done, final ok
|
Final | 4/3/2015 | 4/3/2015 | 4/3/2015 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt called, shall add receptacle in upper bedroom, strap riser at garage, concrtete will be dry to see meter main
|
Electrical Rough-In | 3/9/2015 | 3/9/2015 | 3/10/2015 | P | PASS |
Rex Boyles
|
|
|
Floor heat mst bath insp Phone #: ###-#### Inspection requested via web by John VanZandt r/i floor heat ok
|
Final | 2/25/2015 | 2/25/2015 | 2/25/2015 | P | CANC |
Cevyn Recla
|
|
|
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt Wrong inspection, needed RI not final
|
Electrical Rough-In | 2/25/2015 | 2/25/2015 | 2/25/2015 | P | PASS |
Cevyn Recla
|
|
|
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt
OK to cover Garage,
For service to garage, 250.32 (B) Ungrounded Systems. The equipment of an ungrounded separately derived system shall be grounded and bonded as specified in 250.30(B)(1) through (B)(3). (1) Grounding Electrode Conductor. A grounding electrode conductor, sized in accordance with 250.66 for the largest derived ungrounded conductor (s) or set of derived ungrounded conductors, shall be used to connect the metal enclosures of the derived system to the grounding electrode as specified in 250.30(A)(5) or (6), as applicable. This connection shall be made at any point on the separately derived system from the source to the first system disconnecting means. If the source is located outside the building or structure supplied, a grounding electrode connection shall be made in compliance with 250.30(C).
|
Rough-In Permanent Service | 12/16/2014 | 12/16/2014 | 12/16/2014 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Garage not framed yet. House only with unfinished basement rough in ok cover p/s u/g n ok
|
Issue PAID IN FULL permit | | | 12/16/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/16/2014 | | DONE |
|
|
|
This permit was created on the web by John VanZandt
|