Final | 4/9/2015 | 4/10/2015 | 4/10/2015 | A | PASS |
Bob Reichert
|
|
|
CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn ok final
|
Rough-In Permanent Service | 2/2/2015 | 2/2/2015 | 2/2/2015 | A | PASS |
Cevyn Recla
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn corrections made, RI OK, PS,UG, N, OK
|
Rough-In Permanent Service | 1/29/2015 | 1/30/2015 | 1/30/2015 | A | FAIL |
Cevyn Recla
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn called contractor 300.4(1) Bored Holes. In both exposed and concealed locations, where a cable- or raceway-type wiring method is installed through bored holes in joists, rafters, or wood members, holes shall be bored so that the edge of the hole is not less than 32 mm (11/4 in.) from the nearest edge of the wood member. Where this distance cannot be maintained, the cable or raceway shall be protected from penetration by screws or nails by a steel plate(s) or bushing(s), at least 1.6 mm (1/16 in.) thick, and of appropriate length and width installed to cover the area of the wiring.
|
Electrical Rough-In | 1/13/2015 | 1/14/2015 | 1/14/2015 | A | PASS |
Rock A. Hudson
|
|
|
THIS IS THE UNDER SLAB FOR THE KITCHEN ISLAND ONLY Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover
|
Issue PAID IN FULL permit | | | 1/13/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/13/2015 | | DONE |
|
|
|
This permit was created on the web by Bob Glenn
|