Final | 6/14/2015 | 6/15/2015 | 6/15/2015 | A | PASS |
Bob Reichert
|
|
|
Temp pole permit never finaled. Thanks Jeff. Phone #: ###-#### Inspection requested via web by Andrea Creek ok final
|
Final | 5/12/2015 | 5/13/2015 | 5/13/2015 | A | FAIL |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek 225.32-garage needs disconnect means at a readily accessable location nearest the pointo entrance and be labeled accordingly as garage disconnect. 422.31(B)-water heater needs lockoff on breaker or disconnect at unit. 314.20-extension boxes needed at kitchen backsplash so as not to exceed 1/4 inch to finsish surface. 406.9(B)(1)-in use covers shall be listed "extra heavy duty"
|
Rough-In Permanent Service | 3/5/2015 | 3/5/2015 | 3/5/2015 | A | PASS |
Bob Reichert
|
|
|
Thanks, Jeff Creek ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek called about front soffit lights, told electrician that u/g from house to garage shall be inspected, ri ok, p/s u/g n ok
|
Issue PAID IN FULL permit | | | 2/25/2015 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/25/2015 | | DONE |
|
|
|
This permit was created on the web by Andrea Creek
|